Vacuum Interrupters Inc can provide you a replacement vacuum interrupter (vacuum bottle interrupter), for virtually any manufacturers' medium voltage vacuum circuit breaker or vacuum contactor.*
We carry many vacuum interrupter replacements in stock; and can provide you a vacuum interrupter pole assembly and replacement vacuum interrupter parts or components for virtually any manufacturers' medium voltage circuit breaker. Our engineers can also design replacement or custom vacuum interrupters for obsolete circuit breakers.
Soluciones para todas sus necesidades con interruptores de vacÍo. Informacion-en-Espanol
Click on the headings below for links to more information on our vacuum interrupter replacements for specific manufacturers' circuit breakers and contactors.
-
Vacuum Interupters for General Electric ® - GE ® Vacuum Circuit Breakers and Motor Control Vacuum Contactors
-
We stock replacement vacuum interrupters for GE - General Electric vacuum circuit breakers and motor control vacuum contactors including type VB - VB1 - VVC - PVD - LimitAmp - Power/Vac ® circuit breaker and contactor.
Examples include:
• 43A vacuum interrupter replacement used in in the General Electric VB and VVC vacuum bottle pole assembly, part number 0186L0739P043 and 78005152378 55C679806G1RP. Our RVI-43A is a replacement for the GE Power Vac 43A2 43A4 43A5 43AN 43B3 PV-43A PV-43B vacuum interrupters.
• 52A1 vacuum interrupter replacement used in the GE VB-4.16-250 Power Vac vacuum circuit breaker. The 52A1 is a component in GE vacuum bottle pole assembly, part numbers 0282A7310G001, 0282A2751G073, 0282A2751G074, 0282A2751G041, 0282A2751G042, 0282A2751G063, 0282A2751G064, 0282A2751G077, 0282A2751G078, 0282A2751G081, 0282A2751G082, 0282A2751G053, 0282A2751G069.
• 55B532571P1 vacuum interrupter replacement used in the GE Vacuum Limitamp ® Contactor CR193C ( CR193C910L205050U ) - 800A vacuum contactor. The 55B532571P1 is a component in General Electric Limit Amp vacuum bottle pole assembly, part number 55C679810G1RP.
• 55B532575P1 vacuum interrupter replacement used in the GE Vacuum Limitamp Contactor CR193B ( CR193B110L00505BU )- 400Amp vacuum contactor. The 55B532575P1 is a component in General Electric Limit Amp vacuum bottle pole assembly, part number 55C679806G1RP.
• PV-74A vacuum interrupter replacement for the GE Limitamp AC Motor Controller's PowerVac PV-74A vacuum interrupter (aka PV74A or PV 74A) that is part of GE vacuum bottle assembly part number 55C679806G1RP.
• PV 40A1 vacuum interrupter replacement for the PV 40A1 vacuum interrupter (aka PV-40A1 or PV40A1) p/n 0186L0739P055 used in the GE PowerVac VB 13.8-500 and VB1 13.8-500 vacuum circuit breaker that is part of assembly part numbers 0282A2751G052 or 0282A2751G0G54 or 0282A2751G0G68.
• RP-914 vacuum interrupter bottle used in the GE Limitamp CR193C 800A vacuum contactor. The RP-914 is a component in the GE 55C679810G1RP vacuum interrupter bottle assembly.
-
Vacuum Interrupters for Eaton ® / Cutler Hammer ® / Westinghouse ® Vacuum Circuit Breakers and Motor Control Vacuum Contactors
-
We stock replacement vacuum interrupters for Eaton / Cutler Hammer / Westinghouse type VCP - VCPW - R Type - DVP - DHP-VR AMPGARD ® vacuum circuit breaker and contactor.
Examples include:
• 5259C21H01 vacuum interrupter replacement used in Cutler Hammer / Westinghouse AMPGARD Vacuum Break SJ Series - 360A. The 5259C21H01 is a component in Westinghouse / Cutler Hammer vacuum bottle pole assembly, part numbers 2147A47G03 or 2147A47G13 or 2153A02G02 or 2153A02G01.
• 5259C33 vacuum interrupter replacement used in Cutler Hammer / Westinghouse AMPGARD Vacuum Break SJ Series , SJA50VW430. The 5259C33 is a component in Westinghouse / Cutler Hammer vacuum bottle pole assembly, part numbers 2147A47G03 or 2147A47G13 or 2153A02G03 or 2153A02G04.
• 9910D55 vacuum interrupter replacement used in the AMPGARD Motor Control Vacuum Break SJ Series - 800Amp. The 9910D55 is a component in Eaton / Cutler Hammer / Westinghouse vacuum bottle pole assembly, part numbers 2147A87G03 or 2147A87G13 or 7860A46G23.
• WL23342B and WL23342 vacuum interrupter replacement (aka WL-23342B or WL-23342) used in Westinghouse / ABB vacuum type R Series / VB-D / VBD / R3 / R-3 vacuum circuit breaker.
• WL-35717D vacuum interrupter replacement (aka WL35717D or WL 35717D) used in the 2147A58G02 vacuum bottle pole assembly of the Cutler Hammer SL Series AMPGARD / Triton SL vacuum circuit breaker / contactor - 400A.
• WL-35717F vacuum interrupter replacement (aka WL35717F or WL 35717F) used in the vacuum bottle pole assembly of the Eaton SL Series AMPGARD / Triton SL vacuum circuit breaker / contactor - 400A.
• WL-35875P vacuum interrupter replacement used in the 67A3158G21 vacuum interrupter assembly of the Eaton / Cutler Hammer 50 VCP-TR16 and 50 VCP-T16 vacuum contactor.
-
Vacuum Interrupters for ABB ® / BBC ® / Gould ® / ITE® Vacuum Circuit Breakers
-
We stock replacement vacuum interrupters for ABB / BBC / Gould / ITE type VHK - VHKR - VHKX vacuum circuit breaker.
Examples include:
• 166100-A vacuum interrupter replacement used in ABB type VHK and VHKR circuit breakers.
-
Vacuum Interrupters for Rockwell Automation Allen Bradley ® Vacuum Contactors
-
We stock replacement vacuum interrupters for Allen Bradley vacuum contactor.
Examples include:
• 6C4J6J01 vacuum interrupter replacement used in the Allen-Bradley 1502-V4C1D1 contactor.
-
Vacuum Interrupters for GEC ® Vacuum Circuit Breakers
-
We stock replacement vacuum interrupters for GEC vacuum circuit breaker.
Examples include:
• V801 vacuum interrupter replacement used in GEC vacuum circuit breakers.
-
Vacuum Interrupters for HOW-Yin Square D ® Vacuum Circuit Breakers
-
We stock replacement vacuum interrupters for HOW-Yin Square D type VR - HVC - HVD - VAD1 - VAD2 - VAD3 - VAD4 - VAD5 vacuum circuit breaker.
-
Vacuum Interrupters for Siemens ® / Allis-Chamlers ® Vacuum Circuit Breakers
-
We stock replacement vacuum interrupters for Siemens / Allis-Chamlers type FCV - FSV - MSV - 3AF - GMI vacuum circuit breaker.
|
|
|
|

|
2400V - 38kV
|

|
Up To 3000A
|

|
Compact Design
|

|
Both ANSI and IEC tested vacuum interrupters available
|
|
|

|
Internal Torsion Control
|
|
|
|
|
Visit with us at:
EASA
Gaylord Opryland Hotel & Convention Center
Nashville, TN
June 24-26, 2012
Booth 1519
|
|
Here's How To Determine the Condition of Your Vacuum Interrupters Before They Fail:
Our vacuum interrupter testing technology uses condition based predictive maintenance to determine the condition of your vacuum interrupters.
Visit www.VacuumInterrupterTesting.com
View or download paper
Predicting The Remaining Life of Vacumm Interrupters In The Field
|
|